Wahl 392M Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
392A High Performance Platinum
RTD Thermometer System
RTD Meters
392AHP Series
4
(800) 421-2853 FAX (828) 658-0728 www.palmerwahl.com
Exceptional Accuracy and Long-Term Stability in a
Versatile Meter System with Interchangeable Probes
392AHPF Meter Range: -290° to 1450°F
392AHPC Meter Range: -180° to 788°C
392AHPD Dual Scale Meter Range: -290° to 1450°F (-180° to 788°C)
• Meter Accuracy ±0.1°F/C at 32°F (0°C)
• System Accuracy ±0.25% of reading (392AHP Meter & 202HP Immersion Probe)
• Complete tracing of the platinum standard DIN 43760 to 0.1°F conformity over the
entire temperature range
• Readings updated 2.5 times per second
• Bright 0.33" high-visibility LED display
• Maxi-Temp
®
holds peak temperature reading
• Tough, drop tested meter assembly
• Interchangeable, 4-wire snap-in connection HP Series probes
• Automatic compensation for probe calibration of temperature at ice point and alpha
• Noise suppression circuit
• NIST traceable conforming to ITS-90
The performance of our meters is
warranted for three years against
defects in parts and workmanship.
WARRANTY
392HPC Meter
Application Example with 392AMF
Meter and optional 5-point
Calibrator, CAL392-HT
Wahl invented the portable Platinum-RTD Thermometer
(Pat. No. 4,050,309) to provide exceptional accuracy and
conformity in laboratory and industrial applications. The
392AHP Meter/Probe System represents the ultimate in
Heat-Prober System Performance.
Thousands of 392AHP Heat-Probers are used by various
industries, making critical temperature measurements as
well as calibrating sensors and other instruments.
Use the 392AHP system to calibrate installed sensors, to make quality assurance
tests and to make highly accurate process temperature measurements. An internal
feedback loop maintains system calibration during use. And you can order
additional HP probes at any time without calibration.
The 392AHP features a special noise rejection program for use near high EMF
machines.
See pages 6-7 for complete meter
specifications, options, accessories, and
money saving kits.
See pages 8-9 for Platinum RTD Probe listings.
5-POINT NIST TRACEABLE RTD CALIBRATORS
Assures System Reliability Before Every Measurement
CAL392HP-HT High Temperature Calibrator for 392HP only,
NIST Certificate included
Calibration Points: -58°F, 32°F, 212°F, 284°F, 752°F
-50°C, 0°C, 100°C, 140°C, 400°C
CAL392HP-LT Low Temperature Calibrator for 392HP only
Ice Point to Boil
Calibration Points: 32°F, 68°F, 104°F, 140°F, 212°F
0°C, 20°C, 40°C, 60°C, 100°C
10786-NIST Certificate of NIST Traceability with Test Data.
To request Custom Calibrators with special calibration points,
please contact Customer Service.
392HP Probe Connector
05/08 Rev C
Calibration Services Available
170 Years of Continued Innovation
• Petrochemical
• Food
• Photographic
• Aerospace
• Electronics
• Nuclear Power
APPLICATIONS
Vista de pagina 3