392 High Performance Platinum
RTD Thermometer System
RTD Meters
392HP Series
4
(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com
Exceptional Accuracy and Long-Term Stability in a
Versatile Meter System with Interchangeable Probes
392HPF Meter Range: -290° to 1450°F
3
92HPC Meter
R
ange: -180° to 788°C
392HPD Dual Scale Meter Range: -290° to 1450°F (-180° to 788°C)
• Meter Accuracy ±0.1°F/C at 32°F (0°C)
• System Accuracy ±0.25% of reading (392HP Meter & 202HP Immersion Probe)
• Complete tracing of the platinum standard DIN 43760 to 0.1°F conformity over the
entire temperature range
• Readings updated 2.5 times per second
• Bright 0.33" high-visibility LED display
• Maxi-Temp
®
holds peak temperature reading
• Tough, drop tested meter assembly
• Interchangeable, 4-wire snap-in connection HP Series probes
Automatic compensation for probe calibration of temperature at ice point and alpha
• Noise suppression circuit
• NIST traceable conforming to ITS-90
392HP Meter is FM (Factory Mutual)
approved for potentially explosive
envir
onments.
Class I & II Div. 1, Groups D, F & G.
The performance of our meters is
war
ranted for thr
ee years against
defects in parts and workmanship.
WARRANTY
392HPC Meter
Application Example with 392MF
Meter and optional 5-point
Calibrator, CAL392-HT
Wahl invented the portable Platinum-RTD Thermometer
(Pat. No. 4,050,309) to provide exceptional accuracy and
conformity in laboratory and industrial applications. The
392HP Meter/Probe System represents the ultimate in
Heat-Prober System Performance.
Thousands of 392HP Heat-Probers are used by various
industries, making critical temperature measurements as
well as calibrating sensors and other instruments.
Use the 392HP system to calibrate installed sensors, to make quality assurance
tests and to make highly accurate process temperature measurements. An internal
feedback loop maintains system calibration during use. And you can order
additional HP pr
obes at any time without calibration.
The 392HP features a special noise rejection program for use near high EMF
machines.
See pages 6-7 for complete meter
specifications, options, accessories, and
money saving kits.
See pages 8-9 for Platinum RTD Probe
listings.
5-POINT NIST TRACEABLE RTD CALIBRATORS
Assures System Reliability Before Every Measur
ement
CAL392HP-HT High Temperature Calibrator for 392HP only,
NIST Certificate included
Calibration Points: -58°F, 32°F, 212°F, 284°F, 752°F
-50°C, 0°C, 100°C, 140°C, 400°C
CAL392HP-L
T
Low T
emperatur
e Calibrator for 392HP only
Ice Point to Boil
Calibration Points: 32°F, 68°F, 104°F, 140°F, 212°F
0
°
C, 20
°
C, 40
°
C, 60°
C, 100°C
10786-NIST Cer
tificate of NIST T
raceability with T
est Data.
To request
Custom Calibrators with special calibration points,
please contact Customer Service.
392HP Probe Connector
05/08
Calibration Ser
vices A
vailable
170 Y
ears of Continued Innovation
• Petrochemical
• Food
• Photographic
• Aerospace
• Electronics
• Nuclear Power
APPLICATIONS